Skip to content
DERMATOLOGY / PROCEDURAL SCAR REPAIR

CLINICAL DEVELOPMENT REVIEW · NOVEMBER 2026

Atrophic Scar Treatment in 2026: Clinical Trade-Offs Between Lasers, Microneedling and Subcision

Atrophic scars are not one morphology or one treatment opportunity: rolling, boxcar and ice-pick scars respond differently to release, resurfacing and collagen induction. Split-face randomized studies show meaningful improvement with both lasers and microneedling, but recovery and post-inflammatory pigmentation often decide practical choice.

7 source-linked studies/programsPrimary research sourcesReviewed 11 November 2026
Agrawal et al. · 30-patient split-face study30%Post-inflammatory hyperpigmentation on the fractional CO2 laser side

Versus 6.67% on the microneedling side in this small skin-of-color cohort; an observed within-study difference, not a pooled population risk. Publication ↗

EFFICACYCO2 and Er:YAG devices can deliver greater resurfacing in selected small studies
RECOVERYNeedle-based treatments often reduce downtime and pigmentary events
SEGMENTATIONScar morphology and skin phototype should drive treatment choice and demand models

Scar morphology and recovery burden matter as much as visible improvement

The clinical market for atrophic scars is predominantly procedural, not a conventional drug-development market. Most directly relevant comparative studies evaluate facial acne scars, with smaller evidence for other causes of dermal atrophy. Rolling scars are tethered by fibrous strands, boxcar scars have broad depressed edges, and ice-pick scars are narrow and deep. A device that improves mean grading scores across mixed scars does not necessarily work equally across these morphologies.

In a 2024 split-face study of 30 patients with skin of color, fractional carbon dioxide laser produced larger average improvement in Goodman–Baron scar grading than microneedling. The laser-treated side also had more observed post-inflammatory hyperpigmentation: 30% versus 6.67%. These are side-specific results from a small cohort and should not be advertised as universal complication rates. The study nonetheless captures a commercially decisive trade-off: patients choose not only visible resurfacing but also the length of erythema, temporary pigment change and return to work or social activities.

Other randomized comparisons show why no blanket treatment ranking is justified. A 2016 trial of 46 patients found 1,340-nm nonablative fractional erbium laser and microneedling to have comparable improvement, with longer erythema and more pigmentary events after laser. An ablative Er:YAG split-face trial of 30 patients reported a larger response on the laser side, while microneedling had shorter downtime. In a separate small U.S. study, alternating nonablative fractional laser with radiofrequency microneedling did not significantly improve outcomes over nonablative laser alone.

Many published dermatology trials use local or international registries rather than ClinicalTrials.gov. Their publications remain valid primary clinical sources, but it would be inaccurate to attach unrelated NCT numbers. This article therefore keeps publication-only trial rows separate from U.S.-registry protocols that have no verified published result.

ANALYST VIEW

A scar-treatment market estimate should be segmented by morphology, skin phototype, procedure course and downtime tolerance. Technology sales and procedure revenue are different measures; clinical improvement must be weighed against pigmentary safety and the number of repeat sessions.

Trial designs and outcomes must be read in their clinical setting

Five primary published comparisons and two directly related ClinicalTrials.gov protocols illustrate both observed outcomes and unresolved questions. Rows without an independently verified NCT use their actual publication or non-U.S. registry reference rather than a fabricated NCT identifier.

7 studies
Selected studies and research questions
Study / interventionPopulation and comparisonObserved finding or planned questionSource
Fractional CO2 vs microneedling · skin of color2024 published split-face comparison · 30 patients30 adults, one facial side CO2 laser and other side microneedling; four monthly treatmentsGoodman–Baron grade improved 32.9% vs 9.3%; PIH 30% vs 6.67% (laser vs microneedling).Publication
1,340-nm erbium laser vs microneedling2016 randomized comparator · 46 patients46 facial atrophic acne-scar patients; three monthly laser or microneedling sessionsBoth improved scores; no significant between-treatment difference (p=0.264); PIH noted with laser only.Publication
Ablative fractional Er:YAG vs microneedling2017 randomized split-face · 30 patients30 patients, five monthly split-face treatments, assessment three months after final sessionClinical response reported 70% vs 30% for Er:YAG vs microneedling; less downtime on microneedling side.Publication
Alternating nonablative laser and RF microneedling2024 published randomized split-face · 20 patients20 patients; NAFL alone on one side versus alternating NAFL/RF microneedling on the otherBoth sides improved 20–30% on ECCA measures; no significant between-side difference.Publication
RF microneedling vs fractional CO22026 randomized evaluator-blinded split-face · 33 enrolled33 enrolled and 30 completed; three sessions at eight-week intervals, each facial half assigned one modalityBoth lowered ECCA scores; no significant efficacy difference; RF microneedling produced shorter recovery and fewer pigmentary events.Publication
Subcision with PRP, PDO threads or CO2Randomized three-arm registry protocolPatients with severe atrophic acne scars; combinations of scar subcision with PRP, PDO threads or fractional CO2Comparative Goodman–Baron outcomes planned; published results not independently verified.NCT06227481
Microneedling with topical insulinRandomized protocol · regenerative adjunctPatients with atrophic scars; microneedling with regular-insulin application vs saline after needlingScar-scale change designated as an outcome; no verified comparative result identified.NCT06021275

Source categories are distinguished: primary published clinical outcomes, official trial descriptions, and ongoing investigational programs. No cross-trial efficacy ranking is implied.

What the principal trials can—and cannot—establish

Fractional CO2 vs microneedling · skin of color

This study is especially informative for practices treating patients in whom pigmentary adverse effects are a major concern. The fractional CO2 side achieved more improvement in overall scar grade and in rolling and boxcar morphology, but more patients experienced pigmentation change. Study participants received four sessions and had a relatively short post-treatment assessment window. A clinic should therefore explain both the potential additional resurfacing and the likelihood of greater downtime or post-inflammatory pigment alteration. The data are too small to recommend a single universal device protocol, and they do not establish the durability of benefit years after the treatment course. Primary source: Study details.

1,340-nm erbium laser vs microneedling

A nonablative fractional laser is not interchangeable with an ablative laser merely because both have an erbium wavelength in their name. In this randomized 46-patient trial, three monthly treatments led to similar clinical improvement, but erythema lasted longer after laser and the observed PIH cases were confined to the laser group. The result supports microneedling as a lower-downtime option in selected patients without suggesting that it is equal across every scar subtype. Costs also differ: a capital-intensive laser platform requires utilization and maintenance assumptions that a needle-based practice may not face to the same extent. Primary source: Study details.

Ablative fractional Er:YAG vs microneedling

This comparison demonstrates the appeal of deeper resurfacing and the importance of defining the laser modality. The ablative Er:YAG side showed stronger short-term improvement in the 30-patient split-face design, while the microneedling side had a shorter downtime period. Treatment count was five sessions rather than the three or four used in other publications, and the endpoints differ from the ECCA and Goodman–Baron scores reported elsewhere. The 70-versus-30 response contrast should therefore be interpreted within this study, not converted into a universal device-effectiveness leaderboard. Primary source: Study details.

Alternating nonablative laser and RF microneedling

Combination procedures are attractive to clinics because they can increase the number of services sold during a treatment course, but added complexity needs measurable benefit. In this 20-person study, both halves of the face improved after four treatments, yet the side receiving alternating nonablative laser and radiofrequency microneedling did not outperform nonablative laser alone at the assessed follow-up. That null result is commercially material: selling more modalities does not automatically improve clinical value. Small sample size and limited follow-up prevent definitive conclusions about all combinations, but the findings argue against indiscriminate procedure stacking. Primary source: Study details.

RF microneedling vs fractional CO2

The 2026 randomized comparison clarifies the distinction between similar short-term improvement and different recovery experiences. The mean ECCA score fell from 54.73 to 30.53 on the radiofrequency microneedling side and from 53.67 to 31.03 on the fractional CO2 side, with no statistically significant between-treatment efficacy difference in this exploratory sample. The needle-based side offered shorter erythema, swelling, pain and scab-detachment periods. The registered identifier is ChiCTR2100047207, not an NCT number. The findings support individualized treatment counseling but do not provide definitive long-term recurrence or durability data. Primary source: Study details.

Subcision with PRP, PDO threads or CO2

Subcision has a specific mechanical role for rolling scars: releasing tethering bands that keep a depressed scar anchored. In this registered study, subcision is paired with platelet-rich plasma, absorbable polydioxanone threads or fractional CO2 laser. A study design does not establish which combination is superior; the published outcome would need to show whether benefits exceed subcision alone or differ meaningfully among the add-ons. Practices should also consider bruising, local discomfort, infection prevention and the cost of multiple procedure visits. Registry plans must not be used as marketing proof of an outcome not yet independently checked. Registration: NCT06227481. Primary source: Study details.

Microneedling with topical insulin

This study asks whether a topical adjunct adds value to controlled micro-injury, rather than whether microneedling itself has any clinical effect. The investigators selected a scale-based scar endpoint after microneedling with regular insulin versus saline. It is therefore inappropriate to sell insulin-assisted needling as proven based on the registry listing. Commercially, adjunct products can alter consumable costs and training but require evidence of incremental improvement and safety. Protocol-only programs are useful as pipeline intelligence, not a source of effect sizes. Registration: NCT06021275. Primary source: Study details.

A controlled comparison—not a cross-trial league table

The figure below uses only the comparator arms or sides of one named study. It does not pool unrelated trials, methods or patient populations.

PRIMARY STUDY FIGURE

2024 split-face trial · pigmentary safety

Post-inflammatory hyperpigmentation (%) · same 30-patient cohort
Fractional CO2 laser side30
Microneedling side6.67

Observed incidence in the 30-person study; this is not a pooled device complication rate or long-term risk estimate. Original source ↗

Scar type, modality and pigment risk determine treatment positioning

Rolling scars and tethering. Subcision aims to release the fibrous attachments that pull down the skin. A resurfacing energy device cannot always solve a deep tether on its own; conversely, releasing a rolling scar does not necessarily correct residual surface texture. The case for combination therapy must reflect the scar phenotype and include controlled outcomes rather than purely mechanistic expectation.

Boxcar and ice-pick morphology. Broad boxcar depressions can respond to resurfacing, whereas narrow, deep ice-pick scars may need focal approaches. The 2024 skin-of-color trial reported that ice-pick scars responded least to both CO2 laser and microneedling. Published averages across mixed morphology may therefore exaggerate the expected benefit for a patient whose scars are predominantly ice-pick.

Phototype and pigmentary adverse events. Fitzpatrick skin type and prior pigment disorders influence patient counseling. Post-inflammatory hyperpigmentation is not equivalent to scar worsening, but it can persist and materially affect satisfaction. Lower downtime is commercially valuable even where a procedure achieves somewhat less scar-grade improvement. Protocol intensity, skin preparation and post-treatment care may further change risk.

Study design and durability. Split-face randomized trials reduce between-person variability but bring their own issues: treatments may have visible differences, and scoring may be subjective. Follow-up in the cited papers was generally months rather than years. There is insufficient basis to claim permanent correction, zero recurrence, or universal benefit from multiple-session combination regimens. Clinics should communicate the number of sessions and uncertainty about long-term appearance.

Why procedure markets cannot be modeled like a drug market

The addressable market is created by patient severity, willingness to undertake downtime and ability to pay for a series of procedures. It includes capital devices such as fractional CO2 and Er:YAG lasers, needle-based RF systems, disposable tips, injectables and physician procedure services. The sale of a laser console and the revenue generated from procedures on that console are different financial measures and must not be added without accounting for overlap.

Choice is influenced by patient morphology and skin tone. A clinic treating predominantly darker phototypes may place greater weight on pigmentary safety than a practice prioritizing maximal single-session resurfacing. This alters the potential positioning of nonablative lasers, fractional ablative lasers and microneedling even where average efficacy scales overlap. Cosmetic reimbursement is often limited and geography dependent; there is no sound basis here for a global treatment price, market size or penetration estimate.

Service differentiation can be evidence-driven. Practices may offer subcision for tethered scars, resurfacing for broad depressions and staged interventions for mixed scar types. Clinical studies indicate that adding radiofrequency microneedling to a laser course does not always yield incremental benefit, so a premium package should be linked to a meaningful patient outcome rather than more devices used.

Emerging adjuncts include platelet-rich plasma, threads and topical agents, but protocol publication alone does not prove efficacy. For investment or product planning, the most useful additional evidence would include standardized morphology-specific outcomes, blinded assessments, patient satisfaction, representative darker skin types, prolonged follow-up and the real cost of managing complications.

Clinical documentation can improve segmentation quality. Recording baseline scar type and severity, Fitzpatrick phototype, number of sessions, downtime, satisfaction and adverse pigmentation enables a practice to compare outcomes more responsibly than before-and-after photos alone. Standardized photographs taken under consistent lighting can support evaluation but do not replace blinded scales or longer-term outcomes. Providers capable of demonstrating reliable results for a specific skin type or scar morphology may differentiate themselves without claiming universal superiority for a device.

The practical unit of demand is often a treatment course rather than a patient or a single intervention. A patient with mixed scars may receive staged subcision, resurfacing and maintenance visits, but counting each stage as an independent new patient would overstate the market. Similarly, device-manufacturer revenue, disposable consumables and physician fees should be modeled separately. Better cohort-specific data on treatment completion and patient-reported improvement would make market forecasts substantially more defensible.

EDITORIAL CONCLUSION

Clinical proof must match the commercial claim

Atrophic-scar treatment is a choice among competing clinical trade-offs, not a single best device. Resurfacing may give greater improvement for selected scars, while microneedling can offer shorter downtime and fewer pigmentary events. Morphology-specific outcomes and credible long-term follow-up will be more valuable to the market than unadjusted cross-study efficacy claims.

Trial records and original publications

  1. Fractional CO2 vs microneedling · skin of color — Original peer-reviewed study · No matching NCT ID independently established
  2. 1,340-nm erbium laser vs microneedling — Original peer-reviewed study · No matching NCT ID independently established
  3. Ablative fractional Er:YAG vs microneedling — Original peer-reviewed study · No matching NCT ID independently established
  4. Alternating nonablative laser and RF microneedling — Original peer-reviewed study · No matching NCT ID independently established
  5. RF microneedling vs fractional CO2 — Original peer-reviewed study · No matching NCT ID independently established
  6. Subcision with PRP, PDO threads or CO2 — NCT06227481 · Primary result / trial information
  7. Microneedling with topical insulin — NCT06021275 · Primary result / trial information